• Vertical Fire Fighting Water Pump with XBD Series System 1
  • Vertical Fire Fighting Water Pump with XBD Series System 2
  • Vertical Fire Fighting Water Pump with XBD Series System 3
Vertical Fire Fighting Water Pump with XBD Series

Vertical Fire Fighting Water Pump with XBD Series

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                             Vertical Fire Fighting Water Pump with XBD Series

 

1.Structure of Vertical Fire Fighting Water Pump with XBD Series Description

Portable Fire Fighting Water Pump with XBD Series is a high efficient  water facility has characters of easy installation,saving space, water pool is not required.The pump energy efficient, using I mm converter speed control valve control over a large number of energy saving, the elimination of the high level of secondary pollution of water tanks,water tank eliminates the need to wash the cost and trouble,Water Pump achieve soft-start, start on the grid to reduce the impact of pumps to extend life.

 

2.Main Features of the Vertical Fire Fighting Water Pump with XBD Series

  • Water Supply: Urban water supply, boiler or condensate system, water filtering and distributionwater to water districtin charge of pressurizedhigh-rise building pressurization.

  • Industrial boosting: process water systemcleaning systemhigh pressure washing systemfire system.

  • Industrial liquid conveying: cooling and air conditioning systemsboiler feed and condensate systemsmachine matchingacid and alkali.

  • Water Treatment: Industrial circulating system and processing system, environmental protection water treatment and infiltration analysis system, Ultrafiltration systemsreverse osmosis systemsdistillation systemsseparatorsswimming pool

  • Irrigation: Agriculture irrigation and dewatering, sprinkler irrigation, drip irrigation.

3.Vertical Fire Fighting Water Pump with XBD Series images

Vertical Fire Fighting Water Pump with XBD Series 

4.Vertical Fire Fighting Water Pump with XBD Series Specification

 

modelcapacitypressurespeedeffeciencypowernpsh
(L/s)(MPa)(r/min)(%)(Kw)(NPSH)r(m)
XBD1.8/5-50W50.181450652.23.2
XBD2.7/5-50W50.2714506533.2
XBD3.6/5-50W50.3614506543.2
XBD4.5/5-50W50.451450655.53.2
XBD5.4/5-50W50.541450655.53.2
XBD6.3/5-50W50.631450657.53.2
XBD7.2/5-50W50.721450657.53.2
XBD8.1/5-50W50.811450657.53.2
XBD2.3/10-75W10231450685.53
XBD3.4/10-75W100.341450687.53
XBD4.6/10-75W100.46145068113
XBD5.5/10-75W100.55145068113
XBD6.9/10-75W100.69145068153
XBD8.0/10-75W100.8145068153
XBD9.2/10-75W100.9214506818.53
XBD10.3/10-75W101.0314506818.53
XBD2.9/20-100W200.29145072113.5
XBD4.3/20-100W200.43145072153.5
XBD5.8/20-100W200.58145072223.5
XBD7.2/20-100W200.72145072303.5
XBD8.6/20-100W200.86145072303.5
XBD10.1/20-100W201.01145072373.5

XBD11.5/20-100W

201.15145072453.5
XBD13.0/20-100W201.3145072453.5
XBD4.2/25-125W250.42145073223.5
XBD6.3/25-125W250.63145073303.5
XBD8.4/25-125W250.84145073453.5
XBD10.5/25-125W251.05145073553.5
XBD12.6/25-125W251.26145073753.5
XBD14.7/25-125W251.47145073753.5
XBD16.8/25-125W251.68145073903.5
XBD18.9/25-125W251.89145073903.5
XBD5.8/45-150W250.58145073453
XBD8.7/45-150W250.87145073753
XBD11.6/45-150W251.16145073903
XBD14.5/45-150W251.451450731103
XBD17.4/45-150W251.741450731353
XBD20.3/45/150W252.031450731553
XBD23.2/45-150W252.321450731803
XBD26.1/45-150W252.611450731803

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:What are the meanings of the vacuum pump, the front pump and the main pump?
In operation, the main gas extraction limit vacuum is achieved by the main pump, so we call it the main pump, which plays the main role of the pumpThe front pump is the pump that needs to be opened ahead of the main pump. It is called the pump before the main pump and the pump running the main pumpIf you don't understand, look at your signature and ask again
Q:Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q:What does "anti pump" mean in pump operation?
The working process of the main oil cylinder pushing back and forth against the pump when the S valve (C valve or valve or gate valve skirt) reverse swing, so the piston suction concrete cylinder is in the ash conveying pipe is exactly opposite is the pump suction pump (hopper is concrete and push into the hopper, the desizing)
Q:Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q:What should I pay attention to when buying a pump?
Four, packing inspection1. with the pump supply documents shall include: product certification, specification, packing list, agricultural pumps (such as submersible pumps, centrifugal pumps, mixed flow pumps, self-priming pump etc.) should be "Three Guarantees certificate", the implementation of the production permit (such as pump submersible pump, high pressure pump, high temperature pump 5 pump) we should have a production license.2. plugging of the orifice, to withstand wind and rain invasion, and should be strong, can withstand accidental damage.3. pumps and all supplied bulk parts supplied with the pump shall have the required identification number and shall be clear.4. pairs of oil lubricated bearings, bearings tank oil should be discharged, and fixed with "need oil filling" warning signs.
Q:You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
For the first time, the pump and motor were placed on the base and not fastened (Cu Zhaozheng);Second times, the pump and motor have been tightened, the inlet and outlet flange bolts are not fastened;Third times, the pump runs 24 hours later.
Q:What is the pump, how to classify, mainly used in where?
2. other classification of pumpsThe pump can be divided into two parts according to the position of the pump shaft:1) vertical pump2) horizontal pumpDivided by the number of suction ports:1) single suction pump (single suction pump);2) double suction pump (double, suction, pump)According to the prime mover of the drive pump:1) electric pumps2) steam turbine pump3) diesel engine pump[other details]
Q:How many pumps does the 80cm tank use?
For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
Q:What are the functions of a disposable infusion pump?
When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Centrifugal pumps require a vacuum to produce negative pressure, which allows atmospheric pressure to lift the water surfaceAxial flow pump impeller is thrust on water

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches