• Submersible Pump for Dirty Water with WQ Series System 1
  • Submersible Pump for Dirty Water with WQ Series System 2
  • Submersible Pump for Dirty Water with WQ Series System 3
Submersible Pump for Dirty Water with WQ Series

Submersible Pump for Dirty Water with WQ Series

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                   Submersible Pump for Dirty Water with WQ Series

1.Structure of Submersible Pump for Dirty Water Description

 

WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit  of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.

 

2.Main Features of the Submersible Pump for Dirty Water

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

•Parallel connection and have many models to be chosen for difference flow rate and head

•Horizontally and vertically installation as different pipeline system

3.Submersible Pump for Dirty Water images

Submersible Pump for Dirty Water with WQ Series

4.Submersible Pump for Dirty Water Specification

 

ModelCapacityHeadSpeedEfficiencyPowerOutlet
Q(m3/h)H (m)n(rpm)η (%)Kwmm
40WQ-12-15-1.51215290048%1.540
50WQ-10-10-0.751010290054%0.7550
50WQ-15-15-1.51515290051%1.550
50WQ-15-20-2.21520290051%2.250
50WQ-17-25-31725290053%350
50WQ-20-7-0.75207290062%0.7550
50WQ-22-20-42220290069%450
50WQ-25-10-1.52510290067%1.550
50WQ-25-32-5.52532290049%5.550
50WQ-40-15-44015290076%450
50WQ-40-30-7.54030290062%7.550
65WQ-25-15-2.22515290052%2.265
65WQ-25-28-42528290058%465
65WQ-37-13-33713290060%365
80WQ-29-9-2.2299290048%2.280
80WQ-40-7-2.2407290050%2.280
80WQ-40-15-44015290057%480
80WQ-43-13-34313290065%380
80WQ-50-10-35010290072%380
80WQ-50-25-7.55025290056%7.580
100WQ-50-22-7.55022145063%7.5100
100WQ-50-35-115035145062%11100
100WQ-65-15-5.56515145059%5.5100
100WQ-70-7-3707145075%3100
100WQ-70-22-117022145070%11100
100WQ-80-9-4809145062%4100
100WQ-80-20-7.58020145071%7.5100
100WQ-100-7-41007145075%4100
100WQ-100-15-7.510015145070%7.5100
100WQ-100-22-1510022145061%15100
100WQ-110-10-5.511010145067%5.5100
100WQ-110-15-7.511015145075%7.5100
150WQ-130-30-2213030145069%22150
150WQ-140-7-5.51407145079%5.5150

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:How many kilograms of water pump are there in the automatic washing machine on the market?
Suitable for supporting high pressure sprayer, portable car washer. Water pump with overflow circuit. And comes with pressure switch, overflow switch double insurance
Q:What does the pump mortar do?
In order to effectively reduce the flow resistance of concrete and pipe, to avoid obstruction caused by pipe sticking and to achieve normal pumping, and its role is generally only pumps.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Q:What is the principle of a turbopump?
A machine that converts the energy contained in a fluid medium into mechanical work [turbine]. Also known as turbines, turbines. Turbine is the transliteration of English turbine, derived from the Latin word "turbo", meaning "rotating object". The working conditions of turbines are different from those of the employed ones, so their structure types are various, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) that is mounted on a turbine shaft and has blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work. According to the turbine working fluid used can be divided into different turbine (used as a power source of Hydropower Station) and steam turbine (used in thermal power plant, ship propulsion), gas turbine (used as jet propulsion, ship power, and power plants, with a small peak load power station and air turbine (only) as a small power).
Q:Why does the centrifugal pump close the pressure to start?
The flow is zero (i.e. off dead) minimum, the highest lift power; with the outlet valve opening increases, flow increases, the lift, power and efficiency are increased, the maximum value (usually in the vicinity of the highest rated flow point)
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
Pump flow: the volume of liquid discharged per unit time.(3) volume efficiency of pump: the ratio of actual output flow of pump to theoretical flow rate.
Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
(1) pump connected outside pipes, containers, pipes, joints and other leakage test instrument, large leakage, rotary gas plug exhaust sound big, and the gas and oil mist discharge, should find leakage cancellation.(2) the assembly of rubber of intake pipe is not proper, damage or aging should be adjusted or replaced.(3) plug hole, the vacuum degree can be decreased, put the oil, remove the tank, loosen the nozzle plate, pull out the oil inlet nozzle, dredge oil hole, try not to use cotton wipe parts.(4) the vacuum system has serious pollution, including containers, pipes and so on. It should be cleaned.(5) the spring of the vane is broken and should be adjusted.
Q:What flowmeter is installed after the pneumatic diaphragm pump?
The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches