• SBW Full Automatic Compensation Voltage Stabilizer System 1
SBW Full Automatic Compensation Voltage Stabilizer

SBW Full Automatic Compensation Voltage Stabilizer

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
5000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Feature

 

This series large power voltage regulator is an energy-saving new product developed by our company by absorbing the advanced technology of Western Europe. It is provided with two systems of manual/automatic dual control, direct putout and stabilizing output, with the functions of over/under voltage protection. Delay and error protection etc. it is reliable and suitable for any load .

 

Main technical data

 

Phase NO. : Three-phase four wire system

 

Input voltage : Phase voltage 220V±20% (176-264V)

 

Line voltage :380V±20% (304V-456V)

 

Output voltage : Phase voltage 220V±2-5% adjustable

 

Line voltage 380V±2-5% adjustable

 

Frequency : 50Hz/60Hz

 

Efficiency : ≥95%

 

Response time : ≤1.5s(against 10% input voltage deviation)

 

Ambient temperature : -10°C-40°C

 

Insulation resistance : ≥2m

 

Waveform distortion : Non additional waveform distortion

 

Protection function : Over-voltage, over current, phase shortage, phase-sequence and mechanical failure.

 

Over-load capacity : 1 min. at the rated current of 2 times.

 

Electriciyt-resistance strength : Power frequency sinusoidal is 2000V AC without breakdown and flash over when it lasts 1 min.

 

 

Application

 

It is widely used in the place with large electricity demands such as factories post & communication, schools, hotel etc. Acted as whole voltage-stabilizing or single voltage-stabilizing.

 

Specification

Model  Nos. & kinds of pkg.Package size(cm) Remarks
SBW-10KVA   1Unit/Case 69*85*151
SBW-15KVA 1Unit/Case  69*85*151
SBW-20KVA 1Unit/Case69*85*151
SBW-30KVA1Unit/Case69*85*151
SBW-50KVA  1Unit/Case69*85*151
SBW-60KVA1Unit/Case69*85*151
SBW-80KVA  1Unit/Case75*95*161
SBW-100KVA1Unit/Case75*95*161
SBW-120KVA1Unit/Case75*95*161

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  

Note : If input voltage±30% required buy customers, please specify when ordering.
Special specification can be made according to orders.

Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
220V500W more power saving:Reasons: 1, high voltage, small current, line loss is small; 2, reduce the transformer and other intermediate links, each link has a loss.
Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Q:The transformer zero line has broken, has the result to the household illumination circuit?
The lighting circuit mostly 3 phase unbalanced load, there will be zero drift, zero if the transformer line is broken, part of the lighting circuit to form a series of equipment in the case of two-phase circuit, circuit voltage is decreased and the lighting brightness is not enough, circuit voltage increases, the lamp burned;
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer load end and the power supply terminal is not connected, is safe, and autotransformer primary winding of a share, it is directly connected with the power supply end of the power, not safety.
Q:Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
Q:What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
Q:Why is elevator lighting transformer installed?
1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
Our leading products have obtained Telecom Equipment Network Access License of China Information Industry Department. All our products are qualified and have passed the country surveillance bureau examination. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Zhejiang,China (Mainland)
Year Established 2000
Annual Output Value US$10 Million - US$50 Million
Main Markets South America; Eastern Europe; Southeast Asia; Africa; Mid East; Eastern Asia; Western Europe
Company Certifications ISO9001 Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage 51% - 60%
No.of Employees in Trade Department 3-5 People
Language Spoken: