Portable Fire Fighting Water Pump with XBD Series
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Portable Fire Fighting Water Pump with XBD Series
1.Structure of Portable Fire Fighting Water Pump with XBD Series Description
Portable Fire Fighting Water Pump with XBD Series is a high efficient water facility has characters of easy installation,saving space, water pool is not required.The pump energy efficient, using I mm converter speed control valve control over a large number of energy saving, the elimination of the high level of secondary pollution of water tanks,water tank eliminates the need to wash the cost and trouble,Water Pump achieve soft-start, start on the grid to reduce the impact of pumps to extend life.
2.Main Features of the Portable Fire Fighting Water Pump with XBD Series
Water Supply: Urban water supply, boiler or condensate system, water filtering and distribution, water to water district, in charge of pressurized, high-rise building pressurization.
Industrial boosting: process water system, cleaning system, high pressure washing system, fire system.
Industrial liquid conveying: cooling and air conditioning systems, boiler feed and condensate systems, machine matching, acid and alkali.
Water Treatment: Industrial circulating system and processing system, environmental protection water treatment and infiltration analysis system, Ultrafiltration systems, reverse osmosis systems, distillation systems, separators, swimming pool
Irrigation: Agriculture irrigation and dewatering, sprinkler irrigation, drip irrigation.
3.Portable Fire Fighting Water Pump with XBD Series images
4.Portable Fire Fighting Water Pump with XBD Series Specification
model | capacity | pressure | speed | effeciency | power | npsh |
(L/s) | (MPa) | (r/min) | (%) | (Kw) | (NPSH)r(m) | |
XBD1.8/5-50W | 5 | 0.18 | 1450 | 65 | 2.2 | 3.2 |
XBD2.7/5-50W | 5 | 0.27 | 1450 | 65 | 3 | 3.2 |
XBD3.6/5-50W | 5 | 0.36 | 1450 | 65 | 4 | 3.2 |
XBD4.5/5-50W | 5 | 0.45 | 1450 | 65 | 5.5 | 3.2 |
XBD5.4/5-50W | 5 | 0.54 | 1450 | 65 | 5.5 | 3.2 |
XBD6.3/5-50W | 5 | 0.63 | 1450 | 65 | 7.5 | 3.2 |
XBD7.2/5-50W | 5 | 0.72 | 1450 | 65 | 7.5 | 3.2 |
XBD8.1/5-50W | 5 | 0.81 | 1450 | 65 | 7.5 | 3.2 |
XBD2.3/10-75W | 10 | 23 | 1450 | 68 | 5.5 | 3 |
XBD3.4/10-75W | 10 | 0.34 | 1450 | 68 | 7.5 | 3 |
XBD4.6/10-75W | 10 | 0.46 | 1450 | 68 | 11 | 3 |
XBD5.5/10-75W | 10 | 0.55 | 1450 | 68 | 11 | 3 |
XBD6.9/10-75W | 10 | 0.69 | 1450 | 68 | 15 | 3 |
XBD8.0/10-75W | 10 | 0.8 | 1450 | 68 | 15 | 3 |
XBD9.2/10-75W | 10 | 0.92 | 1450 | 68 | 18.5 | 3 |
XBD10.3/10-75W | 10 | 1.03 | 1450 | 68 | 18.5 | 3 |
XBD2.9/20-100W | 20 | 0.29 | 1450 | 72 | 11 | 3.5 |
XBD4.3/20-100W | 20 | 0.43 | 1450 | 72 | 15 | 3.5 |
XBD5.8/20-100W | 20 | 0.58 | 1450 | 72 | 22 | 3.5 |
XBD7.2/20-100W | 20 | 0.72 | 1450 | 72 | 30 | 3.5 |
XBD8.6/20-100W | 20 | 0.86 | 1450 | 72 | 30 | 3.5 |
XBD10.1/20-100W | 20 | 1.01 | 1450 | 72 | 37 | 3.5 |
XBD11.5/20-100W | 20 | 1.15 | 1450 | 72 | 45 | 3.5 |
XBD13.0/20-100W | 20 | 1.3 | 1450 | 72 | 45 | 3.5 |
XBD4.2/25-125W | 25 | 0.42 | 1450 | 73 | 22 | 3.5 |
XBD6.3/25-125W | 25 | 0.63 | 1450 | 73 | 30 | 3.5 |
XBD8.4/25-125W | 25 | 0.84 | 1450 | 73 | 45 | 3.5 |
XBD10.5/25-125W | 25 | 1.05 | 1450 | 73 | 55 | 3.5 |
XBD12.6/25-125W | 25 | 1.26 | 1450 | 73 | 75 | 3.5 |
XBD14.7/25-125W | 25 | 1.47 | 1450 | 73 | 75 | 3.5 |
XBD16.8/25-125W | 25 | 1.68 | 1450 | 73 | 90 | 3.5 |
XBD18.9/25-125W | 25 | 1.89 | 1450 | 73 | 90 | 3.5 |
XBD5.8/45-150W | 25 | 0.58 | 1450 | 73 | 45 | 3 |
XBD8.7/45-150W | 25 | 0.87 | 1450 | 73 | 75 | 3 |
XBD11.6/45-150W | 25 | 1.16 | 1450 | 73 | 90 | 3 |
XBD14.5/45-150W | 25 | 1.45 | 1450 | 73 | 110 | 3 |
XBD17.4/45-150W | 25 | 1.74 | 1450 | 73 | 135 | 3 |
XBD20.3/45/150W | 25 | 2.03 | 1450 | 73 | 155 | 3 |
XBD23.2/45-150W | 25 | 2.32 | 1450 | 73 | 180 | 3 |
XBD26.1/45-150W | 25 | 2.61 | 1450 | 73 | 180 | 3 |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q:What are the meanings of the vacuum pump, the front pump and the main pump?
- In operation, the main gas extraction limit vacuum is achieved by the main pump, so we call it the main pump, which plays the main role of the pumpThe front pump is the pump that needs to be opened ahead of the main pump. It is called the pump before the main pump and the pump running the main pumpIf you don't understand, look at your signature and ask again
- Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
- If you're allowed to spend a minute, you can do it 20 times a minute, and that is, the amount of water you sprinkle at a time (1000) is *20.1000 (ML) *20=20000 ml =20 liters, this is the flow,Here is a formula for you to see,Pump displacement * pump speed = flow,
- Q:How is the pump level of submersible sewage pump determined?
- Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
- Q:What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- Pump downstream equipment design pressure is greater than 3MPa, if it is 400 meters, the downstream equipment design pressure is greater than 4MPa
- Q:Attention should be paid to the use of pumps?
- To carefully check whether there is a crack impeller, impeller fixed in the bearings are loose, if there are cracks and loose, hungry phenomenon should be promptly repaired, if the pump impeller above the soil should also be cleaned
- Q:Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- First of all, we know that pump according to the principle of work is divided into speed and volume type, centrifugal pumps are speed type, and reciprocating pumps are volume type.The centrifugal pump can adjust the flow through the outlet valve and outlet valve opening can determine the pump flow and head performance curve parameters such as specific relationship between the outlet flow and pressure can be provided by the data pump manufacturers endplate that even close the outlet valve of the pump pressure will also have a fixed value, but not allow zero flow pump operation, vibration caused by damage to the pump on the mechanical seal is not good and so easy to cavitation, set the minimum reflux line.
- Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
- Centrifugal pumps are used to transport liquids (or mixtures, waste water, waste materials) from one location to another.
- Q:What flowmeter is installed after the pneumatic diaphragm pump?
- Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
- Q:What are the general water pump failure, how to repair?
- Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.
- Q:What's the difference between non negative pressure and variable frequency water pump?
- No negative pressure is superposed pressure intelligent frequency conversion equipment, pump frequency operation is no negative pressure difference, and the variable frequency pump, variable frequency pump is advanced municipal tap water tank or pool, pump from the tank or pond water pressure to set pressure to the pressure water supply, and no negative pressure directly from water the municipal pipeline, using the original municipal 2~3 kilograms of pressure
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Portable Fire Fighting Water Pump with XBD Series
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches