Specifications Of Ground-sourcing Heat Pump LGN R407C

Details Of Ground-sourcing Heat Pump LGN R407C

 

Model

GSQ-13WH

GSQ-22WH

GSQ-25WH

GSQ-38WH

GSQ-44WH

GSQ-88WH

GSQ-100WH

Cooling Capacity

KW

9

15

18

26

30

60

75

BTU/H

30717

51195

61434

88738

102390

204780

255975

Heating capacity

KW

13

21.5

25

38

44

88

100

BTU/H

44369

73379.5

85325

129694

150172

300344

341300

Water output

L/h

240

470

530

760

940

1800

2100

Refrigerant

Type

R410A or R407C

Weight

Kg

2.2

3.2

3.4

2.6*2

3.4*2

6.8*2

7.5*2

Control method

outside force balance type thermal expansion valve

Power supply

V/HZ

220(380)1(3)/50

220(380)1(3)/50

380/3/50

380/50

380/50

380/50

380/50

Protection function

High and low pressure,  high and low water output, overload, open phase, antiphase, over and lack pressure, anti-frost

Max.operation Current

A

10

13.2

15.5

17.5

33

53

65

Compressor

Type

   EVI Scroll

pcs

--

1

1

2

2

2

4

4

Input power

Cooling

2.2

3.8

4.3

6.5

9

15

17

(KW)

Heating

2.6

4.6

5.2

8.4

11

18

21

The heat source-side heat exchanger

Type

High efficiency spiral pipe heat exchanger 

Water resistance pressure

KPa

38

43

45

50

55

58

58

Water flow

M3/h

2.1

3.5

4.2

5.8

7

15.2

19.3

Connection size

DN

25

32

32

40

40

65

65

Use of side heat exchanger

Type

High efficiency spiral pipe heat exchanger 

Water resistance pressure

KPa

38

43

45

50

55

58

58

Water flow

M3/h

2.5

4.1

5

6.8

8

15.2

19.3

Connetion size

DN

25

32

32

40

40

65

65

Weight

Kg

90

135

155

250

290

600

660

Dimension(LXWXH)

mm

800X650X1100

1000X650X1280

1450X850X1350

Noise

dB(A)

40

45

45

46

48

50

52

Heating: Using Side Water Temp.(In/Out): 30°C/35°C; Heat Source Water Temp.(In/Out): 10°C/6°.
Cooling: Using Side Water Temp.(In/Out):  12°C/ 7 °C;Heat Source Water Temp.(In/Out): 30°C/35°C
The above data is for reference only: specific data is subject to the product nameplate.

 

Advantage Of Ground-sourcing Heat Pump LGN R407C

1.Heating,cooling and daily hot water
In winter, the unit will provide heat for house heating and domestic hot water.
In summer,the unit will provide cooling.
2.Heat capacity range from 13KW to 100KW or 44369 Btu/H to 341300 Btu/H
3.Advanced heat pump technology of High Cop up to 5 or above can Save more than 80% energy consumption compared to traditonal heaters,eg.electric boiler,gas boiler,geyser.
4.Not produce watse, contributuion to CO2 emission control.
5.Intelligent digital control gives you a comfortable operation ( SCADA modbus protocol option )
6.Safe operation with protection functions of high pressure, low pressure, overheating, overload, anti-freezing, phase monitor for three phases.
7.Extremely silent operation with good noise insulation, vibration isolation of the entire refrigeration system and water system.
8.Compact structure for less space occupation and good demountability Easy installation and maintenance
9.Long working life by using brand partsof flexible Japan Hitachi or Sanyo flexible scroll compressor, America Emerson ALCO thermal expansionvalve,Germany stainless steel plate heat exchanger, long working life up to 15 years.
10.IPX4 with good anti-corrosion: durable coating with special case design by using stainless steel bolts and nuts.
11.Warranty: 12 months guarantee for the whole unit.
12.Heat pump production as per Europe EN14511:2007,Product have CE approval and its working efficiency is Certified by TUV.

 

Packaging & Delivery Of Ground-sourcing Heat Pump LGN R407C

Packaging Detai

Packaging Detail Carton and Pallet or As customer request.

Delivery Detail10-15days

 

Usage/Application Of Ground-sourcing Heat Pump LGN R407C

1. Controller of Siemens,Italy ElWELL, CAREL available for Remote keyboard ( indoor control panel).
2. Plate heat exchanger of Sweden SWEP.
2. Germany WILO water pump and SIKA water flow switch from Germany ensure the good quality product.
3. Thermostatic expansion valve or electronic expansion valve.
4. Environmental R410A or R407c refrigerant.
5. Housing color With Silver, Grey, Cream.
ound source heat pump

We mainly use Copeland scroll compressor, it's high efficiency, low noise, stable, and long lifetime.We use plate heat exchanger.The heat pump can work automatically after the first time setting. It’s easy and convenient to use. 

 

 

 

Q:How does the insulation of the storage tank affect the efficiency of a solar water heater?
The efficiency of a solar water heater greatly depends on the insulation of its storage tank. Insulation plays a vital role in minimizing heat loss from the stored water, allowing it to retain heat for longer durations. Consequently, this reduces the need for constant heating and enhances the overall energy efficiency of the entire system. When the storage tank is adequately insulated, it effectively maintains the desired water temperature for extended periods, even during times of low solar radiation or at night. This means that the solar water heater can continuously provide hot water without relying on additional energy sources, such as electricity or gas, for heating purposes. Conversely, insufficient insulation in the storage tank results in rapid heat loss and a significant drop in water temperature over time. As a result, the solar water heater needs to work harder and for longer durations to reheat the water to the desired temperature, leading to increased energy consumption. Additionally, frequent heating cycles can strain the system, potentially reducing its lifespan and incurring higher maintenance costs. In conclusion, a well-insulated storage tank is crucial for maximizing the efficiency of a solar water heater. It minimizes energy wastage by reducing heat loss and ensures a consistent supply of hot water, even during periods of low solar radiation. Investing in high-quality insulation materials and proper installation can significantly enhance the overall efficiency and performance of a solar water heater system.
Q:Can a solar water heater be installed in a mobile home?
Yes, a solar water heater can be installed in a mobile home. Solar water heaters are versatile and can be installed on the roof or in the yard of a mobile home. They use energy from the sun to heat water, making them an eco-friendly and cost-effective option for mobile home owners.
Q:How to correctly use solar water heater
Solar water heater in the use of solar water heaters in the process, people will find that, if cleverly arranged on the water and water, will play a multiplier effect. Just started to use the user may not be clear, a long time, and slowly will find out the experience and law.
Q:Can a solar water heater be used in areas with limited access to reliable suppliers or distributors of solar equipment?
Yes, a solar water heater can be used in areas with limited access to reliable suppliers or distributors of solar equipment. Solar water heaters are relatively simple and can be constructed using locally available materials. Additionally, maintenance and repairs can often be done locally, making them a suitable option for areas with limited resources or infrastructure.
Q:Can a solar water heater be used in areas with limited access to water storage tanks?
Yes, a solar water heater can be used in areas with limited access to water storage tanks. In such cases, alternative methods of water storage or distribution, such as smaller tanks or direct use of heated water, can be implemented to ensure efficient utilization of the solar water heater.
Q:Can a solar water heater be used in apartments or multi-story buildings?
Yes, a solar water heater can be used in apartments or multi-story buildings. However, the feasibility and installation process may vary depending on factors such as available roof space, orientation, and plumbing infrastructure. It is important to consult with professionals to determine the suitability and potential modifications required to accommodate a solar water heating system in such buildings.
Q:What is the required maintenance for a solar water heater?
The required maintenance for a solar water heater typically involves cleaning the solar panels periodically to remove dust and debris, checking and tightening any loose connections, inspecting the insulation and seals for any signs of wear or damage, and ensuring that the circulation pump and controls are functioning properly. It is also recommended to have a professional service the system annually to perform a more thorough inspection and address any potential issues.
Q:Can a solar water heater be used in areas with high levels of air pollution from power plants?
Yes, a solar water heater can still be used in areas with high levels of air pollution from power plants. Solar water heaters rely on the sun's energy to heat water, and the pollution levels in the air do not affect the system's ability to capture and utilize solar radiation. However, it is important to regularly clean and maintain the solar panels to ensure optimal performance, as air pollution can potentially accumulate and affect their efficiency over time.
Q:Can a solar water heater be used in areas with limited access to backup or alternative heating sources?
Yes, a solar water heater can be used in areas with limited access to backup or alternative heating sources. Solar water heaters rely on the sun's energy to heat water, making them a sustainable and cost-effective option in areas where other heating sources may be scarce or expensive. As long as there is sufficient sunlight, a solar water heater can provide hot water without the need for backup or alternative heating sources.
Q:Are there any limitations to using a solar water heater?
Yes, there are some limitations to using a solar water heater. One major limitation is that it relies on sunlight for its operation, meaning it may not be as effective during cloudy or rainy days, especially in areas with low sunlight intensity. Additionally, the initial cost of installing a solar water heater can be higher compared to traditional water heaters, although it can potentially provide long-term cost savings. Lastly, the size and design of the system may require ample space for installation, which could be a limitation for some households with limited outdoor space.
We are a leading manufacturer of a broad range of ground-sourcing heat pump.Our headquarter is in France.Over the past few years, we has enjoyed unprecedented growth due in large part to the support of our valued customers.

1. Manufacturer Overview

Location Shanghai,China
Year Established 1989
Annual Output Value US$2.5 Million - US$5 Million
Main Markets "

Asia;Western Europe;North Africa"
Company Certifications We are a leading manufacturer of a broad range of ground-sourcing heat pump. Over the past few years, we has enjoyed unprecedented growth due in large part to the support of our valued customers.

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai
Export Percentage 1% - 10%
No.of Employees in Trade Department About 1000
Language Spoken: English;Chinese
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords