• Firefighting Water Pump with Trailer Mounted System 1
  • Firefighting Water Pump with Trailer Mounted System 2
  • Firefighting Water Pump with Trailer Mounted System 3
Firefighting Water Pump with Trailer Mounted

Firefighting Water Pump with Trailer Mounted

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                       Firefighting Water Pump with Trailer Mounted

1.Structure of  Fire Fighting Water Pump with Trailer Mounted Description

Fire Fighting Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.

 

2.Main Features of the Fire Fighting Water Pump with Trailer Mounted 

•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel. 
•Standard design is the pump group, the fuel tank, control panel, battery composite type. 
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type. 
•Can be designed according to customer requirement trailer (four or two wheels) moveable type. 

3.Fire Fighting Water Pump with Trailer Mounted images

Firefighting Water Pump with Trailer Mounted

4.Fire Fighting Water Pump with Trailer Mounted Specification

 

Capacity:72 to3170 m3/h
Size:100~800mm
Head:10 to 125 m
Power:30 to 800 kw
Speed:1450 or 2900 r/min

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
Multi line linkage NHBVR-4*1.5 is a positive pressure blower and smoke exhaust machine fire fighting equipment
Q:Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
Calculate or refer to the water pump nameplate that the normal operating current, according to this data exchange switch.2) with 500V shaking table, measuring the cable, motor insulation is in line with the requirements
Q:What does "dual purpose" of water pump mean? Please expert advice
2, the pump must pay attention to maintenance after use, for example, when the pump is used up, the water pump should be put clean, it is best to remove the water pipe, and then rinse with water.5, the water pump on the tape should be removed, and then rinse with water after drying in the light place, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.6, to carefully check whether there are cracks in the impeller, the impeller fixed to the bearing on whether there is loose, cracks and loose if the phenomenon to be timely maintenance, if the water pump impeller should also be above the earth clean.
Q:Is the centrifugal pump large or small?
NPSH is also called cavitation, cavitation is too big to be.3, pump the liquid when working in the impeller inlet will produce vapor due to a certain vacuum pressure, vaporization of the air bubbles in the liquid particle movement under the impact of erosion on the impeller, the metal surface, thus undermining the impeller and other metal, then vacuum pressure is called vaporization pressure, NPSH is excess vaporization pressure of surplus the energy position of the unit weight of the liquid in the pump suction port of. The unit with annotation, (NPSH) r with. The absorption process is necessary NPSH H: pump suction fluid allows the vacuum pump installation height is allowed, in meters.
Q:What are the characteristics of a pipe shield pump?
Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Daily maintenance of concrete pump, that is, routine maintenance in use, including inspection, cleaning, lubrication, fastening, adjustment, leak hunting, supplement of hydraulic oil, etc.. 8.1 hydraulic components inspection, due to the complexity of the equipment, we recommend practical experts to carry out the inspection of hydraulic system. If a fault is found, check the cause and repair the entire loop before proceeding to any operation. - found that oil has diarrhea, excluding leakage reasons. - inspect safety valves, hydraulic systems, steel tubes and hoses, fittings, cylinders, and find any wear and tear (pipe explosion may cause very serious consequences)
Q:What are the ways of hydraulic pumps?
Hydraulic pump is a power component of hydraulic system. It is driven by an engine or an electric motor. It draws oil from the hydraulic tank to form a component of the pressure oil which is sent to the actuating element.
Q:What are the differences between the sewage pump and the clean water pump?
Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
Q:Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q:What flowmeter is installed after the pneumatic diaphragm pump?
According to your entire pipeline system to flow meter ah!How about the pressure, the material, the digital float or what?You must be sure of the size of the flow

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords