• Cutting Sewage Submersible Centrifugal Water Pump System 1
  • Cutting Sewage Submersible Centrifugal Water Pump System 2
  • Cutting Sewage Submersible Centrifugal Water Pump System 3
Cutting Sewage Submersible Centrifugal Water Pump

Cutting Sewage Submersible Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Product Introduction of WQ series Sewage Submersible Pump

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance of WQ series Sewage Submersible Pump

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition of WQ Series Sewage Submersible Pump 

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic of WQ Series Sewage Submersible Pump

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics of WQ Series Sewage Submersible Pump

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

6. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

4)  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

5) Do you have self-priming pumps?

Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.

6) Is it really necessary to fit a bleed valve for the boxes?

It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.Cutting Sewage Submersible Centrifugal Water Pump

Cutting Sewage Submersible Centrifugal Water Pump


Q:How high can the pneumatic diaphragm pump be?
Diaphragm capacity, high temperature, pneumatic diaphragm pump ability, high temperatureMany users do not know how high the temperature resistant diaphragm pump, diaphragm pump either electric diaphragm pump or pneumatic diaphragm pump products it cannot do without diaphragm attachments, diaphragm materials mainly fluorine rubber, rubber, rubber, polyether road three EPDM, PTFE several, if not considering the gas temperature resistant diaphragm made of stainless steel. The temperature to 600 degrees of diaphragm pump diaphragm pump, but must use the diaphragm, so the diaphragm pump can Naiduo high temperature depends entirely on the diaphragm was affected by temperature, following to share various diaphragm pump diaphragm material and different material temperature choice diaphragm pump product right:
Q:The distance from the pump button to the ground
Yellow warning pop-up, indicating that the fire control room has issued alarm information, fire alarm controller (commonly known as the alarm host)
Q:Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q:How to install, operate and maintain the pipeline booster pump?
Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Q:How many pumps does the 80cm tank use?
Mainly look at the flow of the pump, all pumps have flow signs, such as 15L/HThe above is I at random, meaning that 15 litres per hour. You should calculate the volume of your cylinder, that is, the length of the tank, the width and the height of the water surface, the unit is cm. The result is 1000, which is the volume of your fish tank
Q:Why is the sewage pump device coupler?
Advantages of installation and arrangement of sewage pump coupling:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device under the condition of fixed installation, such as pump fault maintenance personnel need to unscrew the screw pump lifting water, repair, or other small pump to pump the water down perfect maintenance, if the water is dirty, it would be difficult for people to go to the next, then the overhaul had great difficulty.
Q:How can I buy a pump?
2, must meet the characteristics of the media requirementsFor the delivery of flammable, explosive, toxic or valuable medium pump, requiring reliable sealing shaft or the use of non leakage pump, such as magnetic drive pumps (without shaft seal, using isolated magnetic indirect drive).For the transmission of corrosive medium pumps, convection components are required to use corrosion-resistant materials, such as fluorine plastic corrosion resistant pump.For conveying pumps containing solid particles, wear resistance materials shall be adopted in convection parts, and clean liquid shall be used for shaft seal when necessary.
Q:What's the word "pump"? Is that what advocates mean?RT
The words should be decided by the object that everyone supports. The supporters are called "fans"; those who support the singers are called "fans"; the people who support "stars" are called "fans". If the idol supported by everybody is called "shadow" and "view",Star of song? It can not be called "what fans", can only be called "fans"!
Q:The working principle of magnetic pump
Structure characteristics1. permanent magnetPermanent magnet operating temperature range is made of rare earth permanent magnet wide (-45 - 400 DEG C), high coercivity, magnetic anisotropy direction is very good, also won't happen in the same demagnetization phenomenon when is close, is a good source of the magnetic field.2. isolation sleeveIn the metal isolation, isolation sets in a sinusoidal alternating magnetic field, in a cross section perpendicular to the direction of magnetic field lines induced eddy current and converted into heat. Eddy current expression is:. The Pe - K constant; eddy current; rated speed of N - T - pump; magnetic drive torque; F - the pressure inside the sleeve; D sleeve diameter; a material resistivity; and the tensile strength. When the pump design is completed, N, T is the given conditions, to reduce eddy current only from F, D, and so on. Non metallic materials with high resistivity and high strength production isolation, in reducing the eddy current effect is very obvious.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords