Range summary

The EosG range of gel technology batteries offers outstanding performance including  a 15+ years design life .

The EosG series batteries is designed based on the Eos series.

Using the polymer gel electrolyte .

Built to the highest standards and compliant with the latest IEC60896-21/22 standard .

This range also offers 100% capacity out-of-the-box and is capable of handling deep discharges for complete peace of mind. The use of flexible  connectors and the ability to be installed  both horizontally and vertically allows for multiple installation possibilities.

Technical features

  • Above 15 years designed life

  • Reliable post sealing structure

  • Excellent charging acceptant ability

  • Excellent performance at extreme high  and low temperature

  • Low self-discharge ability

  • Flexible and convenient installation  with slinky outside looking

 

Type:

  EosG300

Voltage:

  2V

Nominal Capacity:

  300Ah(C10)  300Ah(10 hours rate:)

Length:

  123mm

Width:

  184.5mm

Height:

  360.5mm

Height   with termial:

  372mm

Weight:

  19Kg

Compliant standards

    • IEC60896-21/22

    • BS6290 part 4

    • Telcordia SR4228

    • Eurobat guide

    • UL

    • Manufactured under system ISO9001(TUV)                                          

    Battery installation compliant with:

    • EN 50272-2 or local equivalents

    Main applications

    • Correspondence exchange and transmission system

    • Mobile communication system

    • Power plant and power transformer system

    • Navigation and signaling system

    • Solar energy system

    • Radio and broadcasting station

    • Emergency lighting system

    Products characteristics:

    • Plate special patent calcium and tin  lead alloy and thick plate design

    • Container ABS(V0 optional)

    • Separator AGM

    • Valve EPDR

    • Electrolyte using the polymer gel electrolyte

    • Terminal M8 copper core posts

    FAQ

    What is sulfation of batteries?

    Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

    How long a battery can last?

    The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

    Do batteries self-discharge when not in use?

    All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

     

Q:The role of the battery?
It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
Q:What kind of battery is divided into?
Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
Q:How to determine the battery is good or bad?
General side maintenance has an observation hole if it is green to prove that the battery is normal if it is black to prove that the battery does not save electricity. There is to observe whether there is liquid exudation, if any, proved to be bad. Finally, you can touch the hand, such as feeling the battery around the plane has proved proof bad.
Q:How does battery activation work?
If you are talking about dry batteries, that is, to add sulfuric acid can use the battery (commonly known as water bottles), then it is because the long-term storage so that a high degree of oxidation of the negative board, plus acid will be a high temperature, Low, you can add acid in the pool after the addition of a small current for a long time to charge, you can solve. Generally with 0.05C charge to 3 times can be.
Q:How to repair the battery?
Connect the positive and negative output of the repair instrument to the positive and negative pole of the battery, open the repair instrument, repair the battery. The first repair time should be no less than 48 hours.
Q:What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:How to deal with waste batteries?
In addition to lead-acid batteries, all kinds of batteries are dissolved in sulfuric acid, and then by means of ion resin from the solution to extract a variety of metals, raw materials obtained in this way than the heat treatment method is pure, so the market price is higher, and the battery contains 95% of the various substances can be extracted.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords