• VRLA Battery MP Series Battery  6-GFM-200M System 1
  • VRLA Battery MP Series Battery  6-GFM-200M System 2
  • VRLA Battery MP Series Battery  6-GFM-200M System 3
  • VRLA Battery MP Series Battery  6-GFM-200M System 4
  • VRLA Battery MP Series Battery  6-GFM-200M System 5
VRLA Battery MP Series Battery  6-GFM-200M

VRLA Battery MP Series Battery 6-GFM-200M

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
500000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


 Range summary:

The MP range VRLA batteries is designed with front terminal structure. The perfect design ensures MP series battery the high reliability and makes the installation quite simple and safe when placed on a standard relay rack tray or in a closed cabinet.

MP range VRLA battery is designed with high energy density and suitable for 19", 23" rack or cabinet, and also offers options of top connection and side of monoblocs connection.Mp range battery can be equipped with central gas collection system according to the requirement of customer.

The MP batteries are ensured the quality with NARADA's QA system according to the ISO9001 standard.

VRLA Battery MP Series Battery  6-GFM-200M

Technical feature:

  • AGM technology applied in MP range batteries.

  • Front-access terminal connections for fast and easy installation and maintenance

  • Suitable for 19", 23" rack or cabinet

  • Excellent special lead-tin-calcium formula alloy for Grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full float  service at 25oC(77oF)

 

Type:

  6-GFM-200M

Voltage:

  12V

Nominal Capacity:

  200Ah(C10)  200Ah(10 hours rate:)

Length:

  498mm

Width:

  259mm

Height:

  238mm

Height with termial:

  238mm

Weight:

  71Kg

Compliant standards :

  • IEC60896-21/22

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobatt guide

  • UL

  • Manufactured under system ISO9001(TUV)

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main application:

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Switchgear / utility

  • Other applications to provide integrated stored energy system

Products characteristics:

  • Recommended float charge voltage for 12V battery:

  • 2.25Vpc at 25oC(77oF)

  • Self discharge rate:< 2% per month at 25oC(77oF)

  • Shelf life: 6 six months at 25oC(77oF)

  • Valve regulated system, no water addition needed.

FAQ


What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

How can I evaluate the health and charge state of a battery?

Routine battery examinations divulge irregularities in the charging system as well as in the batteries. The principle method is to examine the electrochemistry of the battery through hydrometric electrolyte inspection. As previously discussed, this important examination cannot be accomplished with sealed absorption or gel batteries. Voltage readings alone require experience to interpret. Hydrometric readings will uncover early warnings of overcharging or overdischarging before batteries are damaged. The state-of-charge and reliability of a lead acid battery can best be determined by the specific gravity of the electrolyte measured directly with a common bulb-type hydrometer with a glass float. We do not recommend the ball float type hydrometer. Specific gravity is a unit of measurement for determining the sulfuric acid content of the electrolyte. The recommended fully charged specific gravity of marine batteries is 1.255 to 1.265 taken at 80ĄăC More than .025 spread in readings between fully charged cells indicates that the battery may need an equalization charge. If this condition persists, the cell is failing and the battery should be replaced. Since water has a value of 1.000, electrolyte with a specific gravity of 1.260 means it is 1.260 times heavier than pure water while pure concentrated sulfuric acid has a specific gravity of 1.835.


 

Q:Maintenance-free battery how to detect it?
When using a maintenance-free battery, it is easy to think that maintenance-free is the idea that no maintenance is required. Maintenance-free Although maintenance costs and times can be reduced, but for the appearance of the clean-up is essential, so that "maintenance-free" more point to the battery inside.
Q:How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q:What is the meaning of the battery above 12v65Ah?
Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
Q:Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.
Q:What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
Q:How does the battery increase the voltage?
You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
Q:What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q:How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q:What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q:Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords