• battery the EosG series batteries EosG300 System 1
  • battery the EosG series batteries EosG300 System 2
battery the EosG series batteries EosG300

battery the EosG series batteries EosG300

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
2000 unit
Supply Capability:
2000000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Range summary

The EosG range of gel technology batteries offers outstanding performance including  a 15+ years design life .

The EosG series batteries is designed based on the Eos series.

Using the polymer gel electrolyte .

Built to the highest standards and compliant with the latest IEC60896-21/22 standard .

This range also offers 100% capacity out-of-the-box and is capable of handling deep discharges for complete peace of mind. The use of flexible  connectors and the ability to be installed  both horizontally and vertically allows for multiple installation possibilities.

Technical features

  • Above 15 years designed life

  • Reliable post sealing structure

  • Excellent charging acceptant ability

  • Excellent performance at extreme high  and low temperature

  • Low self-discharge ability

  • Flexible and convenient installation  with slinky outside looking

 

Type:

  EosG300

Voltage:

  2V

Nominal Capacity:

  300Ah(C10)  300Ah(10 hours rate:)

Length:

  123mm

Width:

  184.5mm

Height:

  360.5mm

Height   with termial:

  372mm

Weight:

  19Kg

Compliant standards

    • IEC60896-21/22

    • BS6290 part 4

    • Telcordia SR4228

    • Eurobat guide

    • UL

    • Manufactured under system ISO9001(TUV)                                          

    Battery installation compliant with:

    • EN 50272-2 or local equivalents

    Main applications

    • Correspondence exchange and transmission system

    • Mobile communication system

    • Power plant and power transformer system

    • Navigation and signaling system

    • Solar energy system

    • Radio and broadcasting station

    • Emergency lighting system

    Products characteristics:

    • Plate special patent calcium and tin  lead alloy and thick plate design

    • Container ABS(V0 optional)

    • Separator AGM

    • Valve EPDR

    • Electrolyte using the polymer gel electrolyte

    • Terminal M8 copper core posts

    FAQ

    What is sulfation of batteries?

    Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

    How long a battery can last?

    The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

    Do batteries self-discharge when not in use?

    All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

     

Q:What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q:The role of the battery?
It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
Q:Maintenance-free battery how to detect it?
Battery pole Pole terminal has corrosive material without treatment, as long as no loose on it. If the appearance of the corrosive material, the inner surface of the terminal will also be corrosion, resulting in increased resistance, affecting the normal battery charging and discharge, it must be promptly processed.
Q:80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q:How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q:How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q:How to repair the battery?
To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches