• Fire Alarm Control Panel System 1
  • Fire Alarm Control Panel System 2
  • Fire Alarm Control Panel System 3
  • Fire Alarm Control Panel System 4
Fire Alarm Control Panel

Fire Alarm Control Panel

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100pcs m.t.
Supply Capability:
10000 pcs per month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Quick Details of Fire Alarm Control Panel

Place of Origin:

 China (Mainland)

Primary Power Supply:

120V or 220VAC 50/60Hz

Standby Batteries:

DC24V 4AH sealed rechargeable batteries

Display:

15 lines x 40 characters LCD

Devices per loop:

192 sensors & modules

 

Specifications of Fire Alarm Control Panel

Addressable Fire Alarm Control Panel
Primary Power Supply: 120V or 220VAC 50/60Hz
Standby Batteries: DC24V 4AH seale

Addressable Fire Alarm Control Panel

Specifications

The powerful OZH4800E addressable fire alarm panel contains 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices.

Primary Power Supply: 120V or 220VAC  50/60Hz       

Standby Batteries: DC24V 4AH sealed rechargeable batteries

Power Supply Output: 24VDC @ 5.0 Amps (4 Amps available for system power)

Display: 15 lines x 40 characters LCD (600 characters total)

 

SLC loops: 2, 4, 6 or 8 (class A, "style 6 or 7" or class B, "style 4")

Devices per loop: 192 sensors & modules

Addresses per panel: 1536 max.

Communication Port: RS232/RS485

Operation Temperature: 10°C~+50°C  Related Humidity: ≤95% (40±2°C)

Dimensions (D * W * H): 110×335×435mm   

Weight: 16Kg.

 

Applictations of Fire Alarm Control Panel

 

The OZH4800E control panel is an analog addressable fire alarm panel using the latest 32 bit microprocessor technology and containing 2, 4, 6 or 8 SLC loops with each loop supporting 192 devices of any combination (sensors or modules). Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.0 amp power supply, 600 characters LCD display, 29 large easy-to-use tactile touchpad for system operation, programming and maintenance, 12 state indicators and a RS232/RS485 communication port. System operations include silencing alarms and troubles, resetting system and manual starting/stopping field equipment. The system's non-volatile event history buffer stores 9999 events for viewing. The system supports a variety of Orena devices: smoke and heat sensors, manual call points, contact input (monitor) modules, relay output modules, dual input/output modules, and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The basic system can be expanded by adding OZF-LCD remote annunciator, OZH48ZL signalling line circuit expander, and optional mini-printer (for printing system reports). The intelligent panel and detectors know the difference between a fire and a dirty sensor. It lets you tailor sensor sensitivity and gives you immediate, pinpoint accuracy for any condition. The powerful OZH4800E system provides you with revolutionary value and performance in addressable sensing technology, reduces nuisance alarms and makes service calls a rarity.

 

Packaging & Delivery

Packaging Detail:

carton

Delivery Detail:

depend on the order quantity

Fire Alarm Control Panel

 

Q:How long does the fire alarm controller come with a battery?
Fire alarm controller according to the capacity of the battery standby time is depending on the size, the fire alarm host usually chose the shenzhen.
Q:Linkage relationship between automatic fire alarm system and fire sprinkler system
Indoor fire hydrant systemIncluding fire hydrant box, hose, gun, usually set up near the fire hydrant button, press the button fire hydrant, notify the fire control center, fire control center can manually start the fire pump, it can automatically start the fire pump automatically in case of linkage controller allows.Fire pump is the most important equipment in the indoor fire hydrant system. There are 3 ways to control the fire:1. fire pump house, strong electricity control box, manual start directly2. fire hydrant button linkage directly, strong electric control box is started directly3. through fire alarm controller remote controlFire linkage system
Q:What is the linkage module of fire alarm controller?
The linkage module that you say should be a linkage control module, one of the relay modules of the fire alarm controller, as well as the isolation module and monitoring module. Installation of fire alarm system, when the object to be protected in case of fire, fire will change parameters of sound and light, temperature and smoke in the region, the detector will be converted into a fire signal corresponding to the monitoring sub station issued, or found after the fire alarm press the manual alarm button to send signals to the monitoring subsystem station.
Q:Fire alarm controller, fire alarm light, how do you need to do not light?
Eliminate fire alarms (such as smoke detector cleaning, manual alarm button reset, etc.)
Q:What line is the byj1*25 special line for fire control room?
Copper core wire, BV wire all can
Q:What is the single area control panel? Fire master!
You are the gas fire extinguishing system used on it, stand alone is the only controller controller to protect a protected area, there are many areas, see the use of fire to it. The role of the controller is to monitor the working status of fire detectors, modules and other external devices, monitors the connection line is normal.
Q:Is the fire control room open with ordinary glass windows?
The door of the control room should meet the requirements of grade a fire prevention as required.As long as the glass meets the standard of grade a fire prevention, it can be installed.
Q:Is there a standard for fire control room personnel in the new fire law?
Under normal working condition, automatic fire sprinkler system, smoke prevention smoke exhaust system and fire control rolling shutter with linkage control should not be set in manual control state. Other fire fighting facilities and their related equipment, such as those set up in manual state, shall be reliably converted to manual control in case of fire.
Q:What are the causes of fire safety problems?
system composition(1) control device: smoke detector, temperature detector, flame detector. (2) manual alarm device: manual alarm button.(3) alarm detector: regional alarm, centralized alarm, control center alarm.
Q:What is the difference between fire alarm system, alarm controller, linkage controller and alarm linkage machine?
The alarm controller is mainly fire alarm, equipped with smoke detector, temperature detector, manual alarm button, fire hydrant alarm button, etc. for fire detection and alarm equipment.
CFXFIRE, i products sell well in Europe, North and South America, Africa and the Middle East and Southeast Asia with it's good price and good service

1. Manufacturer Overview

Location Fujian, China
Year Established 2008
Annual Output Value Above US$ 1 Million
Main Markets North and South America, Africa and the Middle East and Southeast Asia
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shengzhen
Export Percentage 40%
No.of Employees in Trade Department 200 People
Language Spoken: English; Chinese; Spain; Alabic
b)Factory Information  
Factory Size: Above 60,000 square meters
No. of Production Lines 4
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords