• Adapter Flange System 1
Adapter Flange

Adapter Flange

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Ton m.t.
Supply Capability:
3500 Tons per Month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Detailed Product Description

adapter flange

1 Certificate of CE, ISO9001

2 Size:1/16"-76".

3 WT:SCH20,SCH40,SCH80.

4 Stand of ANSI/ASME, MSS

 

The specification of stainless steel flange

 

 

item

 

 standard No.

 

 size

 

 PN

 

 Type

 

 Material

 

 1

 

 ANSI B16.5

 

 1/2"--24"

 

 150-2500LBS

 

 BL,SO,SW,LJ,WN,THD

 

A105,  A350LF2, A182 F11A182 F304/F304L,F316/F316L

 

 2

 

 LONG WN

 

 1/2"--24"

 

 150-2500LBS

 

 Long welding-neck

 

 A105, A350LF2,A182 F304/F304L,F316/F316L

 

 3

 

 ANSI B16.47 A(MSS SP-44)

 

 26"--60"

 

 150--900LBS

 

 BL,WN

 

 A105,  A350LF2, A694,A182 F304/F304L,F316/F316L

 

 4

 

 BS3293-1960 STANDARD

 

 26"--48"

 

 150-600LBS

 

 SO,WN

 

 A105, A350LF2,A182 F304/F304L,F316/F316L

 

 5

 

 ANSI B16.47 B(API605)

 

 26"--60"

 

 75--900LBS

 

 BL,WN

 

 A105,  A350LF2,A182 F304/F304L,F316/F316L

 

 6

 

 ASMEB16.36 STANDARD

 

 1"--24"

 

 300--2500LBS

 

 SO,WN,THD

 

 A105,  A350LF2,A182 F304/F304L,F316/F316L

 

 7

 

 AWWA C207

 

 4"--144"

 

 Class B,D,E,F T/1

 

 PL

 

 A105,A181 A36,

 

A516Gr.60,65,70

 

 8

 

 EN1092-1:20002 STANDARD

 

 DN10-4000

 

 PN2.5,6,10,16,

 

25,40,63,100

 

TYPE01,02,04,05,11,

 

12,13,21,32,33,34

 

 EN10025(S235JRG2),

 

EN10222-2AND3

 

(P245GH ANDP280GH),

 

EN10222-5(1.4303,1.4306,

 

1.4307,1.4401,1.4404,

 

1.4435,1.4541,1.4571)

 

A105/C21/1.0432 C22.8/

 

P150GH/1.0460

 

 9

 

 BS4504 SEC.3.1/1989 STANDARD

 

 NS15-2000

 

 PN2.5,6,10,16,

 

25,40

 

 CODE101,102,104,105,111,

 

112,113,121,132,133,134

 

 BS970 070M20 BS4360

 

GR.43A BS1503-164 GR.490

 

 BS 1503-224 GR.410

 

 BS 1503-304S11

 

304S31 321S31 316S31 316S11

 

 10

 

 BS10-1962 STANDARD

 

 NB10-3000

 

 TABLE D/ E /F/H/J

 

 SO THD BL WN

 

BS1501-161 GR.B AND C BS1633

 

GR.B BS 1503-240

 

GR.240 BS 1503-620 BS3604

 

 11

 

 ISO 7005-1 STANDARD

 

 DN10-4000

 

 PN2.5,6,10,16,20,

 

25,40,50,110,150,

 

260,420

 

 TYPE01,02,03,04,05,11,

 

12,13,14,15,21,32,33,34

 

 ISO2604-1 F8 F9 F13

 

 F18 F22 F49 F62 F46 F59

 

 12

 

 NFE29203 STANDARD

 

 DN10-600

 

 PN2.5,6,10,16,20,

 

25,40,50,100,150,

 

250,420

 

 TYPE01,02,03,04,05,11,12,

 

13,14,15,21,32,33,34,35

 

 NFE29204 BF 42 BF42N

 

BF48 BF48N

 

 13

 

 JIS B2220 STANDARD

 

 10A-1500A

 

 PN5K,10K,16K,

 

20K,30K

 

 SOP(PL) SOH(SO A B C ) WN

 

 JIS G3101 SS41

 

 JIS G3201 SF40A(S20C)

 

 AND SF45A(S25C) JIS G3202 SFVC1

 

AND SFVC 2A

 

 14

 

 DIN STANDARD

 

 DN10-4000

 

 PN2.5,6,10,16,25,

 

40,64,100,160

 

 SO,BL,PL,WN,LOOSE,THD

 

 RST37.2/1.0038/

 

DIN17100C22.8/1.0460

 

A105/C21/1.0432 1.430 

Q:What does flange WN80 (B) -40M mean?
WN represents the flange type "neck flange"; 80 represents the nominal diameter is 80mm; (B) on behalf of the flange and pipe welding end diameter is B series (domestic use series, 89mm), representing 40 of the nominal pressure is 40bar; M represents the seal type is convex.
Q:Must the flange height go along with the standard?
This is certain, everyone valve is standard, and if you flange is not standard, how to bolt holes on the valve ah?
Q:In the heat treatment, "flange" and "oxidation" there is a difference? Or is it just a different name?
First you "flange" is wrong, should be "blue" it should be a kind of oxidation. It is the antirust treatment of metal surface. Should the general are included in the oxidation within barffing.
Q:1. building fire pipe, valve, flange installation is set sixth books, or sets of eighth booksHere is the Shanxi 05 installation 7 Book notes:Three. The following contents shall be subject to other corresponding quotas:2. fire engineering valves, flanges, making all kinds of casing installation, stainless steel pipe and pipe fittings, pipe fittings and pump and pipeline installation, pipeline system strength test and tightness test and flushing executed sixth copies "industrial pipeline project" the corresponding quota.3. fire hydrant pipes, outdoor water supply pipes and water tank production, installation, implementation of eighth copies of the "water supply and drainage, heating and gas projects" corresponding projectsI would like to ask "fire engineering valve, flange installation" and "building fire pipe valve, flange installation" there is a difference between what?
Construction of fire pipes, valves, flanges installed, no doubt, should be carried out eighth volumes, but with fire pumps connected pipes, flanges, valves should be carried out sixth volumes, the pump inside the pipe. Valves and flanges shall be executed in sixth volumes.Shanxi Province, the 05 installment of the quota Description: "fire engineering valves, flanges, making all kinds of casing installation, stainless steel pipe and pipe fittings, pipe fittings and pump and pipeline installation, pipeline system strength test and tightness test and flushing to perform sixth copies of" industrial piping "corresponding quota." The fire control works here refer to gas fire extinguishing systems and foam fire extinguishing systems. Such fire engineering and building fire protection system, whether pipe, pipe connection mode, construction process is very different.
Q:Which valves should be fitted with flanges?
In addition to the threaded connection, the welding type, the ferrule, the clamp connection is not suitable for flange, flange, and clamp type, all should be equipped with flange
Q:What does "flange PL25-16" mean? Can you point out the meanings separately?
PL is a representative of welding plate flange general customers list at PL25-16 are basically refers to the flange of the Ministry of Chemical Industry Ministry of machinery usually hit the flange flange DN25 PN16. Ministry of chemical industry is not the car linePL welding plate flange 25 diameter pipe diameter of 32 flange diameter of 3316 represents the flange pressure of 16 kgThe Ministry of chemical standards refer to the European system of HG/T20592-1997 or HG/T20592-2009
Q:Can different sizes of flanges have an interface that allows them to be joined together?
Variable diameter flange, also known as Reducing Flange, and its inner diameter and the standard flange diameter, there are some differences.In engineering, when the standard flange can not match the fittings and pipes, the reducing flange is used.China's national standards flange standard (GB) and chemical industry standard (HG) two categories, the new chemical industry standard HG/T20592 ~ 206352009 flange is used to the EN as the representative of the European standard pipe flanges (nominal pressure expressed by PN) and the United States as the representative of the American ASME system (nominal pipe flange the pressure expressed by Class), between them the nominal size of the feature size is different; moreover, our country pipeline diameter series is also divided and metric Inch series series, there are differences in the nominal size; in addition, when there are special requirements, such as flange instrument joints, when the glass lined the characteristics of some special requirements (give it a separate "glass lining of different diameter flange" HG/T2140-2009 standard). Therefore, the inevitable mixing in the project, the use of reducing the flange diameter of the method is the simplest and most effective solution, thus the emergence of non-standard variable flange.
Q:WN-RTJ what's the full name of the flange?
WN, Weld, Neck, Flange, butt welding high diameter flange;RTJ, ring groove sealing type, sealed with metal ring gasket, used in high-pressure environment.
Q:Flange German standard DIN, pleaseND16 what does that ND mean?It's ND in German standard DIN, not nominal diameter DN
Agree upstairsThe pipe has inner diameter, outer diameter and wall thicknessOutside diameter - wall thickness = bore
Q:In the pipe installation, the three way, the elbow, the big head and the flange do not need the quota?
In industrial pipe installation, three - way, elbow and big head should be calculated separately.
Our company has strong professional technical force, rich experience, integrated data and advanced equipment, as well as high-quality forging, machine-processing, assembling and packing production lines. Our product quality is in full compliance with both national and international standards, and we have obtained the ISO9001-2000 quality certification. Warmly welcome all to come to visit, investigate and negotiate business.

1. Manufacturer Overview

Location Shandong,China
Year Established 2008
Annual Output Value
Main Markets North America
South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
Company Certifications ISO9001:2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port qingda
Export Percentage 81% - 90%
No.of Employees in Trade Department
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords