• 0.6/1kV Power Cable System 1
  • 0.6/1kV Power Cable System 2
  • 0.6/1kV Power Cable System 3
0.6/1kV Power Cable

0.6/1kV Power Cable

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
1000M m
Supply Capability:
1000M Per Week m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Basic Info.

Model NO.:  NYY,N2XRY,VV,VLV,VV22.VLV22,VV32,VLV32
Voltage:  Low and Medium Voltage Cable
Insulation Material:  PVC
Current:  AC Cable
Application:  Industrial
Certification:  ISO
Export Markets:  North America, Southeast Asia, Africa, Mid East, Eastern Asia

Additional Info.

Trademark:  CNBM
Packing:  Standard Export Drum
Standard:  IEC, ASTM, BS, DIN, AS
Origin:  Henan, China
HS Code:  8544492100
Production Capacity:  200km/Month

Product Description

Underground PVC cable

1. Used as power transmission & distribution

2. Standard: IEC, BS, DIN, NFC, ASTM etc

 

Product Details

The electrical cable(electric cable) is mainly have 2 kinds listing as followings:

1). PVC insulated PVC sheath power electric Cable

2)Conductor can be copper or aluminium; Be strands, solid, flexible Insualtion is PVC. The Jacket/Sheath is PVC. Armored or without armored

3)Armoured material: Can be steel tape(sta) or steel wire(swa) or others as your request!

4)The recommended nominal cross section is from 1.5 sq mm to 630 sqmm

5)The core number can be single or multi.The Voltage is 0.6/1kV

6)The long-time working temperature of cable should not be higher than 70 celsius, When core is in short-circuit(max 5s) the temperature should not be exceed 160 celsius, While installation the ambient temperature should not be lower than 0 celsius.

Q:So I'm trying to add a sata hard drive from an older computer in my new one, but I encountered a problem. I have the cable the connects to the motherboard and the hard drive, but when looking at the power connectors for the hard drives, there is only one and it is connected to the main hard drive. Am I missing something that is slapping me in the face here, or is this a design flaw? there are 6 hard drive holders sooooo, it seems that there should be 6 power cords inside, but no. Only one. What do I do?
are you sure there's not 1 power cord with six plugs on it? often the power cables will have connectors all the way down them.
Q:specifically, I am using a router. I lost the original cable...can I use a different one?ThanksMatt
uk is now 230, the ecu voltage. (easily, capacity is transmitted under the Channel from France throughout the frenzy hour, that's a risk simply by fact the Continent is on needed ecu Time; no longer correct on your question yet exciting.) some electronics bought interior the USA of a are marked one hundred twenty?240 and those could be utilized interior the united kingdom with basically a plug adapter. Hair dryers and another home equipment have outfitted in resister circuits and you will pass a swap from one hundred twenty to 230/240. or you elect a converter (no longer reported by way of many electricians different than as an emergency holiday expedient) or a transformer. you may desire to examine up the wattage or amperage or you will burn out the transformer. For digicam battery chargers etc, interior the no longer likely experience they are not twin voltage, you may positioned them interior the one hundred twenty v. socket of a batheroom shaver outlet (those have circuit breakers in them for a million amp or much less). I easily have not viewed any digicam chargers recently that are no longer twin voltage. yet confirm. you need to purchase adapters to extra healthful the unique British electric retailers in drug and equipment shops throughout Britain, and at airports.
Q:summary of why 'power cables' are bad evidence. what happens to people whose whole life has been living close to power lines?
There is none. It's a fraud concocted by Green Party extremists to demonize electricity.
Q:is not giving direct contact to my lights....so i just want to replace the power and ground cables for the headlights.??? please help
The power for the headlights comes from the front fuse/relay box, usually on the drivers side wheel well under the hood. There should be a relay in the box for the headlights.
Q:Our company needs a WELDING CABLE / DC POWER CABLE,50mm fine strand and color blue. Does anyone knows where to buy here in the Philippines? or if you know some suppliers, manufacturers please do let me know. It would help a lot. Thanks
You can buy it from okorder
Q:I just have the power cable for battery, lost the ground cable.. Can I cut from power cable and use for ground? Are they the same thing or different cables.??
yes you could use the power cable for the ground because the power cable and ground cable are the same material, as long as both the same guage size is good to connect. For the ground should be as short as possible to the chassis of the car. ground cable just as important as power to get the circuit DC power circulation.
Q:Many of the complete amplifier kits, example rated for a 700 watt amplifier come with a 10 gauge power cable. Many of the gauge charts from the online car audio techs, would recommend a 4 gauge wire, but they sell the amp kits with the 10 gauge. I guess bigger is better, more efficient and safer for the installation, but I would expect them to add some * adjacent to the kit specs with their recommendation.
Power Cable Gauge
Q:Power cable ZRYJV-4x70 + 1x35 What does it mean? Can you explain it?
2 cable in a variety of environments in the laying of the layout, spacing should meet the design requirements
Q:Wire with a single core copper wire is good, or multi-core good?
In the air defense regulations, the pipelines of the air defense zone need to be treated with the protective wing ring. The bridge frame is designed according to the cable laid in the bridge. The cable size and quantity determine the size and quantity of the casing. Increase the standby, air defense requirements casing with hot galvanized treatment, both sides of the exposed wall shall not be less than 100 mm, wing ring production can refer to rigid waterproof casing or flexible waterproof casing (explosion-proof). The general construction plans will have a clear sign, or should be presented to the Design Institute in the trial.
Q:I have a power adapter that goes to a mixer (Denon DN-MC6000) and reads: INPUT 100-240V ~ 50/60Hz 1.5A, OUTPUT: 12V - 3A. Now I know this is the right adapter but I don't know if I have the right cable that goes from the adapter to the wall. I have one that says 6A 250V~ but I dunno if its the right one. I have a few others but can someone tell me what will be the right one so I don't blow up my mixer :P thanks
This type of power cable can be plugged into any household power between 100 and 240 volts. So, any plug that fits into the wall plug is the right one. In the US and Canada the voltage is 110-120 volts. In the rest of the world 240 volts are used The plug and wire you mention is for the rest of the world. Now look at the adapter where you plug the cable into. Do they fit together? If yes go for it. If not keep looking.
WE always insists on independent research and development and takes "top quality, brand, service and reputation" as our tenet. We are continuously increasing our production capacity and export sales volume. We utilize the latest technologies, in response to the growing demands of customers through the R&D of our product lines.

1. Manufacturer Overview

Location Henan, China
Year Established 1995
Annual Output Value USD121,752,660.10
Main Markets Southeast Asia;Mid East;Domestic Market
Company Certifications ISO9001, ISO14001:2004, OHSMS GB/T28001-2001, CCC

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Tianjin;
Export Percentage 70% - 80%
No.of Employees in Trade Department 21-50 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 100,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range High; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords