Elevator three-drive 650 frequency conversion (also known as external elevator, elevator for short) is widely applied to vertical lifting transportation of personnel and materials, is essential good transportation equipment in industrial or civil buildings, large bridges and vertical shafts, and can be applied in warehouses, high towers and other different occasions in a permanent or semi-permanent way. Compared with other lifting mechanisms, the product features stability, safety, reliability, no requirement on additional arrangement of machine room shaft ways, convenient assembly and disassembly, high carrying flexibility, etc., and particularly has obvious effects of relieving the labor intensity of constructors, accelerating project processes and improving working efficiency.
SC200/200 construction elevator is a high-performance product which is newly researched, designed and launched by our company. The elevator features reasonable design, novel structure, stable operation, complete and reliable safety devices and convenient installation and maintenance, and mainly has the following characteristics:
1. The transmission mechanism is driven by two motors, and pinions and racks are safe and stable due to uniform stress.
2. To ensure the safe operation of the elevator, an overload switch, a speed limit switch and other safety switches are arranged in the circuit; when overload, speed limit and other conditions occur in the operation process, the elevator automatically prevents accidents at once. Each door on cages is provided with a limit switch; when any door is opened abnormally, all the cages cannot start or immediately stop operating.
3. Each cage is provided with an anti-falling safety device which can extremely effectively prevent the cages from falling and ensure the safe and reliable operation of the elevator.
4. The electric control system of the elevator has a simple circuit, is convenient to control and maintain and is reliable. When operating normally, the elevator can be controlled to operate by a handle or button in a cage, can be stopped at any time at any position needing the stop, and can be controlled to stop automatically by upper and lower terminal limit switches at upper and lower terminal stations. When the upper and lower terminal limit switches fail to act, limit switches additionally arranged on the elevator can cut off the power supply in time to stop it in a braking mode.
5. The steel structure adopts a computer-aided design mode and is scientifically and strictly calculated to meet the requirements of reasonable structure, reliable intensity and light weight.
6. The elevator can be self-mounted or make standard knots detached by using a hanger rod on a cage. All the other parts can be conveniently mounted and dismounted, and components are easy to replace.
Attached: construction elevator model compilation method
The model of the elevator consists of class, group, type, feature, main parameter and deformation codes.
Notes: The main parameter code includes rated loading capacity codes of two cages, for example, only one main parameter code is marked on a single cage.
Example 1: SCD120
Representing a pinion-and-rack construction elevator with a single cage, the rated loading capacity of 1,200Kg and counterweight.
Example 2: SC200/200
Representing a pinion-and-rack construction elevator with double cages (each cage has the rated loading capacity of 2,000Kg) and no counterweight.
2、Technical performance parameters
Item | Unit | Parameter/specification | Notes | |
Rated loading capacity | kg | 2×2000 | Double-cage | |
Rated seating capacity |
| 2×18 | ||
Rated hoisting speed | m/min | 34.4 | i=16 | |
Maximum hoisting height | m | 150 | ||
Standard knot size | m | 0.80×0.80×1.508 | ||
Cage size | m | 3×1.5×2.5 | ||
Motor | Model | / | YZZ132L1-4 | Large force |
Power | kw | 13×2×2 | ||
Speed reducer | Center distance | mm | 140 | Large force |
Transmission ratio | / | 1:16 | ||
Protector | Form | / | Progressive | SAJ40-1.2 |
Rated action speed | m/s | 1.2 | Xingxiang | |
Calibrated action speed | m/s | 0.95 | ||
Braking torque | N.m | ≥3000 | ||
Braking distance | m | 0.15~1.40 | ||
Standard knot weight | kg | 145 | ||
Self weight of whole machine | kg | 12000 | 50m |
- Q:How much cable does the construction elevator 44KVA need?
- 44KW three phase power: 79A, BV5X16
- Q:How does the construction lift fall without electricity
- This is not calculated according to the distance, it is calculated speed, when the anti-pendant achieves the rated speed, the pendant should be held automatically. It can't go on.
- Q:What is the meaning of double straps in the construction elevator?
- Used for heavy to offset the hoisting cage weight so as to realize energy-saving province electric hoist, by making use of the fixed pulley for heavy gravity into upward traction hanging basket of traction, so as to reduce the drive motor load, achieve energy saving.
- Q:Can a construction elevator use a single cage
- Can use single hanging cage, an accident is a management issue could not be struck down so many people, if such construction lifter dual-use goods elevator belongs to the people, 19 people find this elder brothers say batter to death then top with manned elevator nor safe, in fact is a regular inspection, site do not have an accident can only say that the site is too lax
- Q:What is the need for the sc200/200 construction elevator cable?
- General is 3 times 16 + 2 * 6, want to know can seek professional construction lift machine cable market manufacturer ask
- Q:Construction elevator positioning should consider which problems
- It is convenient to install the wall with the wall
- Q:Is there a specification requirement for the floor door of the elevator to the floor? How high
- Layer should be made from steel door frame, Shanghai silk screen, and is equipped with solid and reliable locking device, elevator door layer, the process should be hanging cage crew operations, shall not be under the direct control of elevator lift cage's movement. The net height should not be lower than 1.80 m, and the width of the door should not be greater than 120mm.
- Q:What is the main function of the construction elevator safety guard
- When the cage is unexpectedly overspeed, the cage will be stationary on the rail frame and cut off the power supply to ensure the safety of personnel and equipment.
- Q:How does the elevator operate
- Responsible for operating elevator, maintenance, maintenance and safety. See what kind of elevator and workplace you are working on.
- Q:Why is the construction elevator not up to the roof
- The free end of the construction of the lift height is only 7.5 meters high, general construction elevator drive now is the case, so the hoisting cage height and drive around 4.5 meters high, the other national standard construction elevator ceiling limit moves, drive above about 1.8 meters away from the top of the rails. So it's the free end of the construction elevator that can't satisfy the roof. As long as they can set up effective adhesion measures, they can also get on the roof.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Elevator Three-Drive 650 Frequency Conversion
- Loading Port:
- Qingdao
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 12 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords