aised Floor with HPL finish Steel flooring
Model: HGD600
Dimension: 600×600×35/30(mm)
This product is made of quality steel plate, which is stretched forming, point welded and plastic sprayed with bubble cement filler filled in its inner cavity. The fire-resistant decoration plates that can endure high temperature adhere to its surface with conductive chips embedded around it. The pedestals and cross beams are wholly plated with zinc and the height of pedestals is adjustable and can be self-locked.
TYPE | Concentrated Load | Impact Load | Ultimated Load | Uniform Load | Rolling Load | |||
LB | N | KG | N | N | N/㎡ | 10passes | 10000passes | |
HGD600-Q | ≥800 | 3550 | 363 | 670 | ≥9400 | ≥14680 | 3560 | 2670 |
HGD600-B | ≥1000 | 4450 | 453 | 670 | ≥11970 | ≥16900 | 4450 | 3560 |
HGD600-Z | ≥1250 | 5550 | 567 | 670 | ≥14360 | ≥22240 | 5560 | 4450 |
HGD600-CZ | ≥1500 | 6660 | 680 | 780 | ≥17950 | ≥26690 | 6670 | 5560 |
Features
Designed specially for computer room&clean room
Excellent rolling load & ultimate load performance
Light weight cementitious fill makes panels solid and quiet
Completely non-combustible
Black electrodeposition cathodic epoxy paint finish for life time protection
Class A flame spread and smoke development rating
Wide range of finishes available
Applicable Fields
Computer rooms, programmed control equipment rooms, electrical-controlled classrooms, places that have requirements of dust-proof and anti-static, and fields with aerial requirements.
Pedestal and Stringer
Installed Example
HPL Colour Card
8063 |
8117 |
8119 |
8132 |
8137 |
8138 |
8144 |
8156 |
8191 |
8192 |
8193 |
8194 |
8213 |
8311 |
8312 |
BEISIDE® computer, server, control room, and general office access floors is China fastest growing raised access-flooring manufacturer. HUIYA help design and create smarter buildings utilizing HUIYA's state of the art raised flooring systems to help organize your voice and data requirements. Create your intelligent building by using the access floor as an open-air plenum. With over 10 years of experience around the construction industry, HUIYA is committed to being part of the solution.
Businesses have responded quickly and dramatically to rapid technological changes over the last several years. Yet, building systems have been slow to accomodate these demands. Changes to office environments continue to be disruptive, slow and wasteful. Repairs to sensitive equipment and data remains unnecessarily high. Environmental efficiency and comfort is more important than ever. HUIYA's Raised Access Flooring systems eliminate the need for embedded wiring and provides instant access to wiring and cabling, allowing for quick and easy reconfiguration of your office space. HUIYA has the technology to address advances in electronic work flow, conservation and occupant comfort.
Why an Access Floor?
* Construction programmes are reduced by at least two weeks per floor due to elimination of a sand cement screed.
* As warm air rises, considerable cost savings are achieved by an underfloor air plenum delivering conditioned air exactly where it is needed - compared with the traditional uneconomic alternative of forcing conditioned air from the ceiling.
* Maximum flexibility for the installation and reconfiguring of services to equipment and workstations a matter of hours.
* In new construction the use of an access floor for total service distribution reduces the overall building height by about 13%. Or, for the same height, you can increase the number of floors.
- Q:An electrostatic pad (static skin to be separated by a large amount of static electricity installed in the installation of an electrostatic buckle, such as an electrostatic pad length of 5M? The More
- Should be two meters then a static buckle!
- Q:Network room anti-static floor, how to do grounding
- Look at your project requires no special high engineering grade requirements, in the anti-static floor of the outer ring supporting feet around a circle of copper and then access to the outdoor underground lightning protection grounding. The supporting feet of the electrostatic floor can be connected by wire or copper. Engineering level requirements on the need for each floor at least one support feet are directly connected with copper to the outdoor underground lightning protection grounding copper and copper rods.
- Q:Ceramic surface anti-static floor What are the characteristics
- Ceramic surface anti-static floor is widely used in all kinds of high-end machine room. Is the use of anti-static tiles as a surface layer, paste in the steel floor board or composite board base (particleboard, cement particle board, calcium sulfate plate, etc.) processed from an overhead floor. Its advantages are: anti-static, no radiation, anti-aging, no dust, pollution, bearing capacity, strong decorative. And the wiring is convenient, the most important is the economic and durable. Ceramic surface anti-static floor is divided into ceramic all-steel anti-static floor, composite ceramic flooring. Two kinds of flooring belong to the ceramic surface anti-static floor, with the time when there are different options. Ceramic Antistatic Flooring Features: 1. Anti-static: The porcelain anti-static floor system resistance is stable and lasting. 2. Resistance to pollution: the porcelain brick surface by improving the product raw material formula, reduce the pores and reduce the small pores and the surface of the brick coated with a layer of special paint, so that the juice is difficult to penetrate the internal, thus solving the "dirty" Old problem. 3. No radiation: tested, without radiation elements 4. Decorative strong: more varieties of brick color, relative to the ordinary room floor, a single color, a better decorative 5. Anti-aging: ceramic anti-static floor quality , Hardness of Mohs 7 degrees, the service life of more than 60 years.
- Q:How to clean the room floor
- PVC permanent anti-static floor maintenance and maintenance 1, is strictly prohibited with the nail shoes walking on the floor. 2, is strictly prohibited hard objects, hardware on the floor characterization, in particular, equipment transport routes and the installation of equipment around the top of the blessing Lennon locusts Wei Chuan even to cushion plywood, and floor scratches and oil pollution. 3, the floor construction is completed, handling machinery and equipment is strictly prohibited machinery and equipment in the floor drag Sassafras. 4, is strictly prohibited with a solvent spray paint the surface of the floor. 5, the production area should wear soft shoes or feet into the work area, prevent dust into the workplace. 6, is strictly prohibited permeability of the ink, mechanical oil pollution floor surface. 7, to prevent the weight of the trailer on the floor surface pressure, the production of tires selected tires to avoid easy to decolorize the vinyl tires, the proposed use of nylon tires. 8, the surface of the floor there is pollution, with gasoline, wash clean, decontamination powder cleaning the floor surface, and then the surface of anti-static wax light treatment. 9, the floor is generally cleaned once a year, and then on the anti-static floor wax lighting maintenance treatment.
- Q:Seeking a large sample of static flooring cad
- There is no problem with paid offer
- Q:Room cabinet from the UPS distribution cabinet to take power, anti-static floor below the need to put a socket? Please recommend several commonly used
- Put a PDU on the line
- Q:Anti - static floor acceptance criteria
- (2) the floor surface without scratches, no coating off, no damage to the edge; (3) after the pavement as a whole should be stable and solid, the staff of the floor and the floor should be clean, no dust, relics; (4) the edge of the floor should ensure that a straight line, adjacent floor dislocation is not greater than 1mm; (5) adjacent floor block height difference of not more than 1mm.
- Q:Anti-static PVC board where the use of, please give details of Thank you very much! The The Questions added: or what type of business with anti-static board, the best example Thank you ~ ~ more
- Generally used for the production of anti-static floor, electronics and semiconductor industry used a lot, is the most cost-effective anti-static floor materials....
- Q:How to remove the clothes static, so that clothes do not close
- Hang some metal on clothes ...
- Q:Brief description of anti-static floor function and construction practices?
- Google Encyclopedia some, very detailed ...
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Raised Floor with HPL finish Steel flooring
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 4000 g/m²
- Supply Capability:
- 50000 g/m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords