radar distance measurement GUIDEPULS67-18

radar distance measurement GUIDEPULS67-18

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
5000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.

Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.

Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.

 

Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel. 
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.

 

Input:

 

the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.

 

When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)

Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.

 

4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire) 

 

CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.

 

Q:What's the role of carbon brushes in electric tools?
In addition to induction type AC asynchronous motors, there is no outside. Other motors are provided, as long as the rotor has a reversing ring.The principle of electric power generation is that a magnetic field cuts a wire to produce an electric current in the wire. The generator cuts the wires by rotating the magnetic field. A rotating magnetic field is a rotor, and the wire to be cut is a stator.
Q:What devices must be available for all hand held electric tools?
Hand held electric tools, insulation measures are in good condition, must be equipped with qualified leakage protection device, forbid to change the power cord and plug, use special flow switch box.
Q:What safety problems should we pay attention to when using electric drills or hand-held power tools?
All of the wires must be more tough and durable rubber covered wire. When the wire enters the shell of the motor, the rubber ring is used to protect the insulation layer of the wire from being worn out.
Q:How about plug wires and cables for power tools?
Class I tools are common type power tools with a rated voltage of over 50 volts. Class I tools not only rely on basic insulation but also include an additional safety measure in the protection against electric shock. The method is that the accessible conductive parts and protection has been installed in the fixed line in the (ground) wire together, make accessible conductive parts in the basic insulation does not become damaged in the charged body. Plug for three pin plug type tool.
Q:What's the name of an electric tool for riveting screws into wood? Not understand!
An electric drill can be used! But it can't adjust the torque! There are four types of professional screw twisting tools!
Q:What's the difference between a flashlight and an electric screwdriver?
As the mechanical component, the electric screw driver can work without the electric batch power supply, and the batch power supply provides the energy and the related control function for the electric screwdriver. Drive the motor. Since the parameters of the motor are different, the speed will be different when the power of the batch power supply is the same.
Q:How are hand powered tools classified into class I, class II, class III?
Nowadays, class I hand held power tools are virtually discontinued. The class II hand-held electric tools are widely used. Class II hand held electric tools are generally used on special occasions such as wet environments, metal containers, etc..
Q:Is there an electric tool for screwing bolts? It's bolts, not screws
The 2 floor is good! Electric wrenches, pneumatic wrenches, front with prominent slot, you can clamp different sleeve, find the corresponding sleeve with buckle...
Q:What kind of power tools are hand drills? 1, 2 or 3?
You can see the cable plug, the aluminum shell is inserted three I tools, is grounded, the aluminum shell and some II tools, because it has a plastic insulation between the stator and the aluminum shell, so it is the installation of two wire plug.
Q:What are the commonly used rotor types for power tools?
Power tools are mainly divided into metal cutting, power tools, grinding power tools, assembly of power tools and railway power tools. Common electric tools electric drill, electric grinder, electric wrench and electric screwdriver and hammer, impact drill, concrete vibrator, planer. Accessories for each power tool: rotor, stator, gear, bearing, switch, carbon brush, carbon brush holder, carbon brush cover, power cord. Go down and stop repeating.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords