• GUIDEPULS63-4 26 GHz radar liquid level meter System 1
  • GUIDEPULS63-4 26 GHz radar liquid level meter System 2
  • GUIDEPULS63-4 26 GHz radar liquid level meter System 3
  • GUIDEPULS63-4 26 GHz radar liquid level meter System 4
  • GUIDEPULS63-4 26 GHz radar liquid level meter System 5
  • GUIDEPULS63-4 26 GHz radar liquid level meter System 6
GUIDEPULS63-4 26 GHz radar liquid level meter

GUIDEPULS63-4 26 GHz radar liquid level meter

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
5000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.

Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.

Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.

 

Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel. 
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.

 

Input:

 

the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.

 

When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)

Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.

 

4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire) 

 

CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.

 

Q:Is the motor of an electric tool the alternating current motor or the direct current motor?
To be exact, they are generally series motors, so they are alternating current motors. The direct current motor is usually used as charging tool and driven by DC motor. Also useful for three-phase motors, such as concrete vibrators, are three-phase motors.If it is DC power supply, must have rectifier power ah, because the power supply is 220V AC, must be rectified into DC to use.
Q:What safety problems should we pay attention to when using electric drills or hand-held power tools?
The motor inlet shall be provided with a ground or zero connection device.(4) wearing shoes must be worn while wearing protective gloves such as insulating gloves.(5) each use of tools must be strictly checked.
Q:Is Li Xiang power tool good?
I was doing a power tool, you said this is a good point, I suggest you buy brand electric tools, East into a really good, but you buy when I suggest you go to the East into the store to buy if to go to other places to buy will be expensive, and not necessarily the East into true. There are a lot of imitation in East into sell, buy electric tools as long as buy a good brand of machine authentication
Q:What's the name of an electric tool for riveting screws into wood? Not understand!
An electric drill can be used! But it can't adjust the torque! There are four types of professional screw twisting tools!
Q:Is BOSCH's power tools good or MAKITA's power tools?
MAKITA electric tool features:The utility model has the advantages of small noise, strong power, good performance, long service life, light body, strong and durable, easy operation and convenient repair. The utility model is the necessary high-quality product for professional personnel or amateur DIY personnel.
Q:What is the working principle of power tools?
AC motor, AC motor of induction motor, its strong induction current (eddy current) magnetic field generated in the rotation of the magnetic force on the rotor copper bar, continuous cutting, according to Lenz's law, the induced current has the effect of relative motion occurs against the rotor magnetic field and the rotor is, with the magnetic field and rotation. But the rotor rotation speed of the high speed magnetic field does not transform, otherwise it will not be able to cut the copper lines.
Q:How are the I, II, and III classes of power tools classified?
In accordance with the electric shock protection methods, electrical equipment is divided into the following 4 categories:0 category. The device relies solely on basic insulation to prevent electric shocks. There are no ground terminals on the live conductors of the 0 types of equipment.
Q:What are the common rotors of power tools?
Power tools are mainly divided into metal cutting, power tools, grinding power tools, assembly of power tools and railway power tools. Common electric tools electric drill, electric grinder, electric wrench and electric screwdriver and hammer, impact drill, concrete vibrator, planer. Accessories for each power tool: rotor, stator, gear, bearing, switch, carbon brush, carbon brush holder, carbon brush cover, power cord. Go down and stop repeating.
Q:What kind of power tools are hand drills? 1, 2 or 3?
I class: in the prevention of electric shock protection, in addition to relying on basic insulation, but also the need for zero protection.Class II: the tool itself has double insulation or insulation without the need to protect the ground.Class III: Powered by a secure, ultra low voltage power supply, no voltage higher than the safety supply voltage is generated within the tool.The above is the classification of insulation categories.
Q:What are the commonly used rotor types for power tools?
Concrete vibrator: concrete used for pouring concrete foundations and reinforced concrete members to eliminate porosity and increase strength. The high-frequency disturbing power of the electric direct acting vibrator is driven by an electric motor to rotate the eccentric block, and the motor is powered by an 150Hz or 200Hz intermediate frequency power supply.The planer: used for planing wood or wood structure, mounted on the bench can be used as a small bench plane. The planer cutter shaft by the motor shaft through the belt drive.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords