Product Classification and Main Technical Specification
1), product classification
Voltage level: 40.5kV, 72.5kV, 126kV.
Current level: 1250A, 2000A, 3150A.
Auxiliary earthing switch type: none earthing switch, left earthing switch, right earthing switch, double earthing switches.
Rotation type: rotation with an angle of 90 degree, rotation with an angle of 180 degree.
2), Main Technical Specifications
Technical Specifications | Product Type | GW5-40.5Ⅲ | GW5-72.5Ⅲ | GW5-126Ⅲ |
Rated voltage kV | 40.5 | 72.5 | 126 | |
The rated current A | 1250, 2000, 3150 | |||
Disconnector | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Grounding switch | Rated peak withstand current kA | 100, 125 | ||
Rated short-time withstand current (RMS)kA | 40, 50 | |||
Rated short circuit duration s | 4, 3 | |||
Rated short-time power frequency withstand voltage (RMS) kV | to earth | 95 | 160 | 230 |
across open contacts | 118 | 200 | 230+70 | |
Rated lightning impulse withstand voltage (peak) kV | to earth | 185 | 350 | 550 |
across open contacts | 215 | 410 | 550+100 | |
minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector | 53 | 94 | 164 | |
rated terminal static mechanic load N | longitudinal level | 800, 1000 | 800, 1000 | 1000, 1250 |
Horizontal level | 500, 750 | 500, 750 | 750 | |
Vertical force | 750 | 750 | 1000 | |
switching micro-capacitance current A | 2 | 2 | 2 | |
switching micro-inductance current A | 1 | 1 | 1 | |
switching busbar for current transfer A (busbar transfer voltage 100V) | 400V, 2500A, 100 times | |||
Radio interference level | less than 500 μV | |||
Mechanical life | 3000 | 3000 | 3000 | |
single pole weight (kg) | 120 | 200 | 260 | |
Note: All applied to an altitude of 2000m |
- Q:DC transmission equipment
- Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
- Q:Transmission lines are not electrical equipment?
- If you are satisfied, please accept it as a satisfactory answer
- Q:What is the power equipment in the distribution room?
- which is mainly used for the distribution of the electric energy of the low-voltage users, and the utility model is provided with a medium voltage input line (a small number of outlets)
- Q:Are electric wires and cables belong to distribution equipment?
- Distribution equipment (Electrical Equipment) is in the electric power system of HV switchgear, generator, transformer, power circuit, circuit breaker, low voltage switch cabinet, distribution board, switch box, control box and other equipment collectively.
- Q:Transmission and transformation equipment
- Power transmission and transformation of the protection of the main transformer, relay protection devices, lightning arrester, etc..
- Q:Main equipment of high voltage direct current transmission
- At present, most of the converter adopts thyristor thyristor rectifier, which is composed of three phase bridge rectifier.
- Q:AC distribution equipment including distribution box
- protection of the power supply system is between the power supply and the load are connected, disconnected, conversion
- Q:High and low voltage distribution equipment
- High voltage distribution equipment: high voltage fuse; high voltage isolation switch; high voltage load switch; high voltage circuit breaker.
- Q:Transmission system and distribution system
- Simply put, you can distinguish between the end of the cable to the use of electrical equipment (motor, power box) is the distribution system to the substation, transformer is the transmission system
- Q:Power distribution equipment should be prepared before the blackout?
- The actual operation, one man operation, another voice.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
66kV V Type Switch Disconnector with electric operating mechanism
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches