Product Classification and Main Technical Specification

 

1), product classification

 

Voltage level: 40.5kV, 72.5kV, 126kV.

 

Current level: 1250A, 2000A, 3150A.

 

Auxiliary earthing switch type: none earthing switch, left earthing switch, right earthing switch, double earthing switches.

 

Rotation type: rotation with an angle of 90 degree, rotation with an angle of 180 degree.

 

2), Main Technical Specifications

 

Technical Specifications

Product Type

GW5-40.5

GW5-72.5

GW5-126

Rated voltage kV


40.5

72.5

126

The rated current A


1250, 2000, 3150

Disconnector

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Grounding switch

Rated peak withstand current kA

100, 125

Rated short-time withstand current (RMS)kA

40, 50

Rated short circuit duration s

4, 3

Rated short-time power frequency withstand voltage (RMS) kV

to earth

95

160

230

across open contacts

118

200

230+70

Rated lightning impulse withstand voltage (peak) kV

to earth

185

350

550

across open contacts

215

410

550+100

minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector


53

94

164

rated terminal static mechanic load N

longitudinal level

800, 1000

800, 1000

1000, 1250

Horizontal level

500, 750

500, 750

750

Vertical force

750

750

1000

switching micro-capacitance current A


2

2

2

switching micro-inductance current A


1

1

1

switching busbar for current transfer A (busbar transfer voltage 100V)


400V, 2500A, 100 times

Radio interference level


less than 500 μV

Mechanical life


3000

3000

3000

single pole weight (kg)


120

200

260

Note: All applied to an altitude of 2000m


Q:DC transmission equipment
Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
Q:Transmission lines are not electrical equipment?
If you are satisfied, please accept it as a satisfactory answer
Q:What is the power equipment in the distribution room?
which is mainly used for the distribution of the electric energy of the low-voltage users, and the utility model is provided with a medium voltage input line (a small number of outlets)
Q:Are electric wires and cables belong to distribution equipment?
Distribution equipment (Electrical Equipment) is in the electric power system of HV switchgear, generator, transformer, power circuit, circuit breaker, low voltage switch cabinet, distribution board, switch box, control box and other equipment collectively.
Q:Transmission and transformation equipment
Power transmission and transformation of the protection of the main transformer, relay protection devices, lightning arrester, etc..
Q:Main equipment of high voltage direct current transmission
At present, most of the converter adopts thyristor thyristor rectifier, which is composed of three phase bridge rectifier.
Q:AC distribution equipment including distribution box
protection of the power supply system is between the power supply and the load are connected, disconnected, conversion
Q:High and low voltage distribution equipment
High voltage distribution equipment: high voltage fuse; high voltage isolation switch; high voltage load switch; high voltage circuit breaker.
Q:Transmission system and distribution system
Simply put, you can distinguish between the end of the cable to the use of electrical equipment (motor, power box) is the distribution system to the substation, transformer is the transmission system
Q:Power distribution equipment should be prepared before the blackout?
The actual operation, one man operation, another voice.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches